Technical data

Reliable ultrasound technology data are contained in one place.

Immersion Chamber

Function

It is the first process of multi tank ultrasonic cleaner to immerse and clean the item.

Specification

  • Tank Size (mm): 400(L) X 260(W) X 280(H)
  • Rated Power & Capacity: 3Ø 220V 2.5KW 1EA
  • Type & Length: Seize Heater, 350mm
  • Position of the heater & thermostat

Temperature Range

Type of Solvent FRON-113 FRON-11 TCE-11 PCE TCE MEC WATER
Range(Below) 30 18 60 50 30 45

Check Point

Symptom Cause Action
In case that the temperature does not rise
(Check if an electricity flows)

Malfunction of the thermostat

Disconnection of the heater

Breakdown of the control panel

Add a cleaning solvent to the vapor chamber

When disconnected, change the heater Repair

Circulate the coolant

In case that a short circuit occurs

Bad insulation of the heater

Peeling off of the heater cable's sheath

Bad insulation of the thermostat

Check if it is insulated after the heater is separated

Change or insulate the cable

Change the thermostat, or dry it

In case that the cleaning solvent is overflowed into the next chamber

Blockage of the overflow piping line

Remove the sewage in the pipe

Cautions

  • Do not permit power of the heater in the state of the heater is exposed.
    If the heater is overheated, it may be broken, or the cleaning solvent is acidified so it may lose a function as a solvent.
  • Remove any dirt on the surface of heater when cleaning.