Specification
Temperature Range
| Type of Solvent | FRON-113 | FRON-11 | TCE-11 | PCE | TCE | MEC | WATER |
|---|---|---|---|---|---|---|---|
| Range(Below) | 30 | 18 | 60 | 50 | 30 | 45 |
Check Point
| Symptom | Cause | Action |
|---|---|---|
| In case that the temperature does not rise (Check if an electricity flows) |
Malfunction of the thermostat Disconnection of the heater Breakdown of the control panel |
Add a cleaning solvent to the vapor chamber When disconnected, change the heater Repair Circulate the coolant |
| In case that a short circuit occurs |
Bad insulation of the heater
Peeling off of the heater cable's sheath
Bad insulation of the thermostat
|
Check if it is insulated after the heater is separated Change or insulate the cable Change the thermostat, or dry it |
| In case that the cleaning solvent is overflowed into the next chamber |
Blockage of the overflow piping line |
Remove the sewage in the pipe |